IPRストリッピングシステム:隣接面削合ストリップ 1.0(12本)

$399.00 $573.00
Interproximal Reduction Orthodontic Sterilizable
 
$399.00 $573.00$174.00の割引が適用されます

IPR Strips with 4:1 Reciprocating Contra Angle Handpiece Set

Achieve greater control throughout your orthodontic interproximal reduction procedures with the MR.BUR IPR Strips & Kaneiko 4:1 Reciprocating Contra Angle Handpiece Set. Combining diamond abrasive IPR strips with a Japan-engineered reciprocating handpiece, this clinical solution is designed to support controlled enamel reduction, interproximal space creation, and proximal surface refinement during orthodontic and clear aligner treatment.

Whether you are managing mild to moderate dental crowding, creating space for clear aligner therapy, or refining proximal enamel surfaces, this combination brings together progressive abrasive strip selection and controlled back-and-forward handpiece movement. It supports a more structured and efficient IPR workflow while helping clinicians maintain tactile control throughout treatment.

Clinical Advantages:

  • Controlled interproximal enamel reduction
  • 4:1 reciprocating handpiece mechanism
  • Progressive diamond abrasive strip system
  • Suitable for orthodontic and aligner treatment
  • Supports conservative space creation
  • Smooth back-and-forward oscillating motion
  • Low-vibration handpiece design
  • Multiple strip thicknesses and grit selections
  • Supports proximal contouring and finishing
  • Practical solution for routine orthodontic IPR

What's Included in This Set?

  • MR.BUR IPR Strip System 1.0 – Diamond abrasive strips with progressive grit selections for controlled interproximal reduction.
  • Kaneiko 4:1 Reciprocating Contra Angle Model IPR Handpiece – Designed to provide controlled back-and-forward reciprocating movement for compatible interproximal reduction accessories.
  • Kaneiko Handpiece Packaging Box – Protective packaging for the handpiece.
  • Manual Guide Book – Operating and maintenance instructions.
  • Strips Removal – Maintenance accessory for the handpiece.

IPR Strip System 1.0 (NEW)

Introducing MR.BUR IPR Strip System 1.0, a clinically structured solution for interproximal reduction in orthodontic treatment. Designed for controlled enamel wear, IPR Strip System 1.0 supports minimally invasive space creation between teeth, helping clinicians manage alignment challenges with precision and predictability.

IPR Strip 1.0 is mainly indicated for orthodontic stripping procedures, where enamel is reduced in a measured way to create the minimum spaces necessary for treatment. This approach is especially useful in cases of dental crowding and for teeth that require space from 0.05mm to 0.4mm to be correctly positioned during orthodontic therapy.

Clinical Indications:

  • Orthodontic stripping
  • Interproximal reduction (IPR)
  • Creation of minimum necessary space for treatment
  • Correction of mild to moderate dental crowding
  • Improved positioning of misaligned teeth
  • Use in various types of orthodontic treatment

Clinical Advantages:

  • Minimally invasive enamel reduction technique
  • Controlled interproximal space creation
  • Flexible and versatile strip system
  • Available in different thicknesses and grain sizes
  • Designed to improve precision in interproximal opening procedures
  • Supports safe and progressive wear in orthodontic cases

IPR Strip System:

15 Micron Super Fine (Yellow) 

  • 0.10 mm double-sided interproximal opening
  • Extra fine progression for conservative enamel reduction

30 Micron Fine (Red)

  • 0.20 mm double-sided interproximal opening
  • Fine progression for further controlled reduction

46 Micron Medium (Blue)

  • 0.30 mm double-sided interproximal opening
  • Medium progression for greater space development

90 Micron Coarse (Green)

  • 0.40 mm double-sided interproximal opening
  • Coarser progression for advanced interproximal reduction

Material and Performance:

MR.BUR IPR Strip 1.0 uses diamond abrasive strips designed for efficient wear on hard tooth surfaces. Diamond powder is used as the abrasive component, supporting both interproximal reduction and high-quality finishing where needed.

The system is designed to combine flexibility, progressive cutting control, and clinical efficiency, helping orthodontists perform interproximal reduction in the right measure.

Product Highlights:

  • High performance interproximal reduction system
  • Progressive step sequence for controlled treatment workflow
  • Diamond abrasive technology
  • Various thicknesses and grain sizes
  • Flexible and versatile for orthodontic use

The MR.BUR IPR Strip System 1.0 is packaged in 12 pcs/pack.

Details Specification Diameter
15 Micron (Yellow) Super Fine 0.10mm Double Sided
30 Micron (Red) Fine 0.20mm Double Sided
46 Micron (Blue) Medium 0.30mm Double Sided
90 Micron (Green) Coarse 0.40mm Double Sided

Kaneiko 4:1 Reciprocating Contra Angle IPR Handpiece

The Kaneiko Reciprocating Contra Angle IPR Handpiece is engineered to provide controlled, stable, and precise movement for orthodontic interproximal reduction procedures. Its 4:1 contra-angle reduction system converts rotational input from a compatible E-type dental motor into controlled reciprocating movement. This mechanism supports predictable instrument handling, tactile feedback, and progressive enamel reduction during suitable IPR procedures.

Designed with a stable shaft and cartridge system, ceramic bearing, ISO-standard connector, and E-type international connection, the handpiece combines practical compatibility with low-vibration performance. For orthodontists and general dentists performing regular IPR procedures, it offers an alternative to manually working interproximal strips through every stage of treatment.

Key Features of the Kaneiko Model IPR

  • 4:1 reduction contra-angle system
  • Back-and-forward reciprocating movement
  • Designed for orthodontic IPR procedures
  • Stable shaft and cartridge mechanism
  • Ceramic bearing for smooth operation
  • ISO-standard connector
  • E-type international-standard connection
  • Maximum specified speed of 10,000 rpm
  • Noise level below 65 dB
  • Low-vibration operation
  • Autoclavable up to 135°C
  • Designed for controlled proximal finishing

How Does the 4:1 Reciprocating Contra Angle Handpiece Work?

The Kaneiko Model IPR receives rotational input from a compatible dental motor and converts it into a controlled back-and-forward oscillating movement. Instead of continuously rotating like a traditional bur, a compatible reciprocating IPR strip moves through the contact area in alternating directions.

This motion allows clinicians to guide the abrasive instrument through narrow interproximal spaces while progressively removing enamel according to the prescribed treatment plan. The reciprocating mechanism is particularly useful when treating crowded teeth, restricted contact points, and proximal surfaces that require careful control of instrument positioning.

The 4:1 reduction ratio supports controlled movement and torque transmission from the dental motor. By combining this mechanism with appropriately selected abrasive strips, clinicians can establish a systematic approach to interproximal reduction while monitoring the amount of enamel removed.

Why Use a Reciprocating Handpiece for IPR?

  • More Controlled Instrument Movement: The reciprocating action supports progressive enamel reduction rather than uncontrolled continuous rotary cutting.
  • Improved Access to Tight Contacts: Compatible thin IPR strips can be guided through narrow interdental spaces with controlled movement.
  • Consistent Clinical Workflow: The handpiece provides a repeatable motion pattern that may reduce the need for extensive manual strip manipulation.
  • Better Handling During Procedures: The contra-angle design supports instrument guidance during suitable anterior and posterior IPR procedures.
  • Patient Comfort: Low-vibration operation and controlled movement can contribute to a more comfortable treatment experience.
  • Practical for Routine Orthodontics: Suitable for clinicians regularly performing aligner-related and fixed orthodontic interproximal reduction.

Kaneiko Model IPR Technical Specifications

Specification Details
Model Number Model IPR
Handpiece Type Reciprocating Contra Angle
Rotation Speed 10,000rpm
Working Air Pressure 0.22-0.3Mpa
Ratio 4:1
Movement Back-and-Forward Reciprocating
Bur Application Size CA 2.35 mm Ø
Connector ISO Standard Connector
Bearing Ceramic Bearing
Available Connection E-type International Standard
Noise Less than 65 dB
Disinfection Autoclave to 135°C

Clinical Applications of the Combined IPR Set

1. Clear Aligner Treatment

Clear aligner therapy frequently requires planned interproximal space creation to support tooth movement, alignment, and treatment progression. The MR.BUR IPR Strip System offers progressive abrasive selections, while the Kaneiko reciprocating handpiece supports controlled mechanical movement with suitable attachments. This combination is particularly relevant for clinicians performing planned IPR during clear aligner treatment.

2. Mild to Moderate Dental Crowding

When indicated by the orthodontic treatment plan, interproximal reduction can provide additional space to help manage certain crowding cases. Using the appropriate abrasive grade allows clinicians to work progressively rather than attempting to achieve the full prescribed reduction in one step. The amount of enamel removed should always follow the patient's individual treatment plan.

3. Anterior Interproximal Reduction

Anterior teeth often require careful interproximal access because of their visible anatomical contours and relatively restricted contact areas. Fine IPR strips can support conservative enamel reduction and proximal refinement. Clinicians should select the appropriate strip thickness and movement technique according to the patient's tooth anatomy and planned reduction.

4. Posterior Interproximal Reduction

Posterior teeth may present wider contact areas and more restricted visibility. A suitably compatible reciprocating strip system can help clinicians manage instrument movement and access between premolars or molars. Progressive strip selection and repeated space measurement remain important for controlled enamel reduction.

5. Proximal Enamel Contouring and Finishing

After the planned space has been created, the reduced proximal surfaces may require refinement to minimize surface irregularities and maintain appropriate tooth contours. Fine abrasive strips and compatible finishing or polishing instruments can support the final stage of the IPR procedure.

Who Should Consider This IPR Set?

  • Orthodontists: For routine planned interproximal reduction during fixed orthodontic and aligner treatment.
  • Clear Aligner Providers: For progressive space creation according to digital treatment plans.
  • General Dentists Providing Orthodontic Services: For conservative proximal enamel reduction when clinically indicated.
  • Multidisciplinary Dental Clinics: For clinics requiring dedicated instruments for interproximal reduction and suitable proximal finishing procedures.
  • High-Volume Orthodontic Practices: For practices looking to standardize the IPR workflow with progressive abrasive selections and controlled reciprocating instrumentation.

Limited Units Available! Order Now and Get a FREE Handle & IPR Opener!

Express shipping 

Cash back

Quality Assurance

Customer service